Spok Messenger Gateways: Comp1/Comp2

Comp Gateways are used for sending and receiving messages from systems using the Comp 1 or 2 protocols.

A Comp port must be created before a Comp gateway can be added. The Comp ports display in the Port list box. For information about Comp ports, please refer to Comp1/Comp2 Ports.

Please note that there is no provision to set the communications parameters, as the Comp CCFP can use only one communication setting.

 

A description of the fields is included below:

Name

The name that appears in the gateway port list.

Protocol Variant

Specifies whether the Comp1 or Comp2 protocol is used.

Port

Refers to the physical connection that this gateway utilizes. If no port appears in this list, you need to configure at least one port to use the Comp protocol.

Baud

Sets the communication rate for serial communications.

Data

Sets the number of data bits for serial communications.

Parity

Sets the type of parity for serial communications.

Stop

Sets the number of stop bits for serial communications.

Max msg length

Determines the longest message that can be sent through this gateway. Messages that exceed this length are either split or truncated, depending on if the Split long messages option is chosen.

Split long messages

Causes messages longer than the maximum message length to be sent as separate sequential messages.

Send Via

This is for Comp2 messages received from an external system. The message can either be forwarded directly to another gateway or default mapping, which uses the ID received as a local ID lookup.

Recipient

This is for Comp2 messages received from an external system. The message is forwarded to the specified recipient.

Gateway enabled

Determines whether or not the gateway is functional. It is convenient to disable this setting to temporarily stop messaging to the Comp device.

 

Adding a Comp Gateway

  1. Choose Interfaces > Comp1/Comp2. The CompX Gateways screen displays.
  2. Click New.
  3. Enter the desired information.

Sample screenshot showing the Comp2 protocol:

 

Sample screenshot showing the Comp1 protocol:

  1. Click Save. The gateway is saved.

 

Editing a Comp Gateway

An existing Comp1/Comp2 Gateway can be edited.

  1. Choose Interfaces > Comp1/Comp2. The Comp1/Comp2 Gateways dialog displays.
  2. Select the gateway to be edited from the list on the left.
  3. Change the desired information.
  4. Click Save. The changes to the gateway are saved.

Deleting a Comp Gateway

Existing Comp1/Comp2 Gateways can be deleted.

  1. Choose Interfaces > Comp1/Comp2. The Comp1/Comp2 Gateways dialog displays.
  2. Select the gateway to be deleted from the list.
  3. Click Delete or press the delete key on the keyboard. The gateway is deleted.