Screen Pops Not Working Due to Corrupted genbridge.ini File
Overview
In some cases, Spok Console screen pop-ups may fail to function on a specific workstation even though all CTI configurations appear correct. One potential cause is a corrupted or misconfigured genbridge.ini file.
Issue Example:
Screen pops were not appearing on a console despite all known-good settings. CTI services were running and matched the expected configuration.
Resolution/Topic
Replace the genbridge.ini file with a known-good copy from a functioning Spok Console workstation. Steps:
1. Navigate to the affected workstation.
2. Rename the existing genbridge.ini file (e.g., genbridge.ini_old) to preserve it. ("C:\Program files (x86)\Amcom\Bin\Genbridge")
3. Copy the genbridge.ini file from a known-working console.
4. Paste the known-good file into the appropriate directory (typically where genbridge.exe resides).
5. Run genbridge.exe as administrator.
6. Restart the CTI service.
Outcome:
After replacing the file and restarting services, screen pops resumed functioning normally.
Related Notes:
· Always verify CTI configuration settings match across working and non-working consoles before making file changes.
· Use SecureLink or another approved method for file transfers if remote access is required.
Related Defects:
N/A